Back-up power generator as a 45 kVA emergency power system with Yanmar engine and external mains/generator switchover
Stock No.: 1359
Completion:
Category:
Notstromaggregat Stationär
Generating Set:
stationary
Gen Set:
silent Set
Technical Data Engine:
Engine Manufacturer:
Yanmar
Engine Type:
4TNV98T
Engine No.:
183813
Engine Power:
37,7 KW
Cooling:
water-cooled
Starting:
electrical 12 V DC
Rotation:
1500 rpm
Fuel:
heating oil EN 590
Fuel Consumption:
9,6 Liter at 100 % load
Emission Standard:
TA-Luft
Engine Size:
L.
Amount of Oil:
L.
Consumption of Combustion Air:
m³/h
Cooling Air Volume:
m³/h
Exhaust Temperature:
°C
Exhaust Gas Quantity m3:
m3
Exhaust Gas Quantity kg:
kg
Technical Data Generator:
Generator Manufacturer:
Stamford AvK
Gen Set:
S1L2N
Gen No.:
X22A042045
Gen Power:
45 kVA
Gen Amperage:
Ampere
Short Circuit Current:
Ampere
Overload:
Ampere
Voltage:
400 / 231 Volt
Voltage Controller:
elektronisch AVR
Power Factor:
cos. - phi 0,8
Rotation:
1500 rpm
Control Unit:
Setup:
automatic start
Functions:
emergency power
Switch:
mains/Gen switch 4 pole
Delivery:
parted separately
Width ca. mm:
Height ca. mm:
Depth ca. mm:
Fuel Tank:
Setup:
baseframe fuel tank with bassin
Width ca. mm:
Height ca. mm:
Depth ca. mm:
Capacity / Litre:
170
Dimensions of unit:
Width ca. mm:
910
Height ca. mm:
1.350
Length ca. mm:
2.200
Weigth ca. KG:
890
Usage:
Stock No:
1359
State:
new
year of manufacture:
New
time of delivery:
ex work
Operating Hours:
Neu
Location:
Verl - Germany
Price plus VAT in €:
on request:
Reserved:
nein / no
delivery contents:
Back-up power unit as emergency power system type: WA Y 50 "S" super soundproofed with approx. 66 db"A" measured in 7 meters with an all-round measurement in 7 meters at 7 measuring points.
Other features:
Tank capacity 170 liters
Oil drip tray in the base frame
mechanical speed controller
Stable additional base frame with forklift pockets
Automatic start with external mains & generator switching 63 amps, in 4-pole design
Function: In the event of a power failure, the start command is sent to the diesel unit. When the nominal speed and nominal voltage are reached, the generator switch is switched on. When the mains returns, the automatic system monitors the mains voltage. When this is stable again, the system switches back to mains operation. The diesel unit is stopped after the cooling time and waits in automatic mode for the next power failure.
The emergency power system as an emergency power supply is ready for operation and available from the Verl warehouse.