Emergency generator as backup generator 600 kVA with Volvo engine TAD 1642 GE in RAL 9010 tank 800 liters

stromerzeuger stromerzeuger stromerzeuger stromerzeuger stromerzeuger stromerzeuger stromerzeuger stromerzeuger stromerzeuger stromerzeuger stromerzeuger
Stock No.: 1295
Language / Sprache
PDF Download
Overview / Übersicht

Completion:

Category: 
Notstromaggregat Stationär 

 
 

Generating Set: 
stationary 

Gen Set: 
silent Set  

Technical Data Engine:

Engine Manufacturer:  
Volvo Penta 

Engine Type:  
TAD 1642 GE-B 

Engine No.:  
201660329 

Engine Power:  
503 KW 

Cooling:  
water-cooled 

Starting:  
electrical 24 V DC 

Rotation:  
1500 rpm 

Fuel:  
heating oil EN 590
Fuel Consumption:  
120 Liter at 100 % load 

Emission Standard:  
TA-Luft  

Engine Size:  
16,12L.

Amount of Oil:  
48 L.
Consumption of Combustion Air:  
2.130 m³/h

Cooling Air Volume:  
36.000 m³/h

Exhaust Temperature:  
456 °C

Exhaust Gas Quantity m3:  
5.664 m3
Exhaust Gas Quantity kg:  
kg

Technical Data Generator:

Generator Manufacturer:  
Stamford AvK 

Gen Set:  
HCI 544 F1 

Gen No.:  
X221355604 

Gen Power:  
670 kVA 

Gen Amperage:  
Ampere

Short Circuit Current:  
Ampere

Overload:  
Ampere

Voltage:  
400 / 231 Volt 

Voltage Controller:  
elektronisch AVR

Power Factor:  
cos. - phi 0,8 

Rotation:  
1500 rpm

Control Unit:

Setup: 
manual start 

Functions: 
emergency power 

Switch: 
gen switch 4 pole 

Delivery: 
set up 

Width ca. mm: 
 

Height ca. mm: 
 

Depth ca. mm: 
 

Fuel Tank:

Setup: 
Internal fuel Tank with Bassin 

Width ca. mm: 
 

Height ca. mm: 
 

Depth ca. mm: 
 

Capacity / Litre: 
800 

Dimensions of unit:

Width ca. mm: 
1.700 

Height ca. mm: 
2.460 

Length ca. mm: 
4.810 

Weigth ca. KG: 
6.500 

Usage:

Stock No: 
1295 

State: 
as good as new 

year of manufacture: 
2024 

time of delivery: 
2025 

Operating Hours: 
10 

Location: 
Verl - Germany 

 
 

Price plus VAT in €: 
on request: 

 
 

Reserved: 
nein / no 

 
 

 
 

delivery contents:

New, soundproofed (69 db"A" (+/- 2.4) as the mean value of an all-round measurement at 7 measuring points) emergency power generator as backup power supply, designed for continuous operation around the clock.

The silencer hood is modular with generous doors for maintenance.
The built-in emergency power control, manufacturer Comap, type IG 200 is designed for uninterrupted reverse synchronization overlapping synchronization with control of your on-site network generator switchover.

Internal day tank (800 liters) in the base frame with drip tray. Optionally with leakage monitoring

Fuel consumption according to Volvo data sheet:

Consumption at 50% approx. 59 liters / hour | sufficient for approx. 13.5 hours
Consumption at 75% approx. 89 liters / hour | sufficient for approx. 8.9 hours
Consumption at 100% approx. 120 liters / hour | sufficient for approx. 6.6 hours
-/-
Speed Control | Speed governor class Electronic G3
exhaust gas temperature | Exhaust gas temperature °C 471
exhaust gas volume flow | Exhaust gas volume m³/h 5,556
Combustion air volume flow | Combustion air volume m³/h 2,280
Maximum exhaust back pressure | Maximum allowed back pressure mbar 100
thermal energy / waste gas | Heat reaction to exhaust week 375
thermal energy / charge air | Heat reaction to charge air KW -/-
thermal energy / cooling water | Heat reaction to cooling water week 187
thermal energy / radiation | Heat reaction to ambient week 18
Cooling air volume flow | Cooling air flow m³/h 36,000